File Version: 3.2
41
/
62
JAKA C Series Hardware User Manual
The control cabinet is equipped with a 16-channel digital PNP input (active high) (DI1-DI16), which supports
isolated signal input. The level signal meets the standard of IEC61131-2 (Type1/2/3) and is used to detect the
input signal level status.
V+ voltage
Low level
High level
24V
0-11V
15-30V
V+ supports external 10-35V power input, and the internal 24V power supply is connected by default. The high
level is ranged from 15 to 30V, and the low level is ranged from 0 to 11V.
Users can also short it to V+ through simple buttons or switches.
Wiring for different types of input signals is different. The specific connection method is as follows:
1.
Dry contact signal as input
Figure 5-8 Dry contact input wiring
When the dry contact is input, one wire is connected to V+, and the other is connected to the DI specified
channel. When the circuit is connected (as shown in the figure, the switch or relay is turned on), the
corresponding indicator on the panel is on. The corresponding indicator will light on in the JAKA Zu APP at the
same time.
2.
PNP signal as input
Figure 5-9 PNP input wiring
The PNP input wiring method is shown in Figure 5-9, with the power wire V+ connected to the terminal V+, the
signal wire to the specified DI channel, and the 0V wire to the panel V-. When a signal is triggered, the
corresponding indicator on the panel is on. The corresponding indicator will light on in the JAKA Zu APP at the
same time.
5.3.4
Digital Output (DO)
1
2 3 4 5 6 7 8
DI(1~8)
V+
P1