Page 46
Operation
TM-4100GE Hardware
8.6.1 Async No Shutter
Vinit trigger starts the first exposure period within one line (1H = 32.5
μ
sec.) and transfers the frame
after a 9.5H exposure. After the first transfer, a new full frame exposure period (67.6
μ
sec.) begins.
Async No Shutter allows for strobe and back-to-back strobing (strobing both before the transfer gate
and right after) applications.
LDV
Ext. Vinit
FDV
Transfer Gate
Analog Video
During FDV Blanking
During Active Video Period
Strobe
Discharge
Summary of Contents for PULNiX TM-4100GE