Page 47
Operation
TM-4100GE Hardware
8.6.2 Internal Shutter Speed Control
The video signal starts with internal VINIT. When the external VINIT pulse is applied, internal VINIT
is latched to HD and the internal VINIT is delayed to set up the shutter speed period. The shutter speed
is controlled by communication software from “1” to “8.” Video output timing starts right after the
internal VINIT and single shots, FDV is output at the internal VINIT timing.
EXT. VINIT
HD
INT. VINIT with shutter speed control
Discharge
Transfer Gate
FDV
Analog Video Sync
Exposure time set by shutter speed
Strobe