GO-5000M-USB / GO-5000C-USB
- 44 -
Note 1: The trigger is input through 6P Optical input. Accordingly, the timing will be changed if
the optical filter is set to the other figures.
Note 2: Other timings are internal operating timing of a camera.
Fig.26 RCT mode timing
8.8 Video Send Mode
The GO-5000-USB has a Video Send Mode and it includes the following operations.
Table-22 Video send mode
Mode selected
Index selection method
Normal
Normal operation
Multi ROI
Up to 5 ROI images can be set up. Each image is output
independently.
Trigger Sequence
Up to 10 indexes can be set for ROI, Exposure Time and Gain.
Select the index by using the Frame Start trigger signal.
Command Sequence
Up to 10 indexes can be set for ROI, Exposure time and Gain.
Select the index number to assign directly by using the
Command Sequence Index command.
Delayed Readout
Up to 7 frames can be stored (8-bit). Each image can be
output by Acquisition Transfer Start trigger timing.
8.8.1 Sequence ROI Trigger
This mode allows the user to define a preset sequence of up to 10 images, each with its own ROI,
exposure time and gain values. This mode has two operation modes.
Mode selected
Index selection method
Trigger Sequence
Select the index by using the Frame Start trigger signal. (The
setting index can be determined by the Next Index setting.)
Command Sequence
Select the index number to assign directly by using the
Command Sequence Index command.
Trigger
CMOS
Exposure
FVAL
Exposure
Active
Exposure Period
t3
t1
t2
t1
t2
t3
10 μs (Min) 102µs
5L
~
6L