GO-5000M-USB / GO-5000C-USB
- 41 -
Minimum interval of the trigger
Read out mode
Minimum trigger interval
Full
16.155 ms
ROI 1/2 (Height=1024)
8.09 ms
ROI 1/4 (Height=512)
4.077 ms
1/2V Binning (Note 1)
8.09 ms
(Note1)
GO-5000M-USB only
Note 1: The trigger is input through 6P optical input. Accordingly, the timing will be changed if
the optical filter is set to the other figures.
Note 2: Other timings are internal operating timing of the camera.
Fig.23 Timed
8.6. Trigger width mode
In this mode, the exposure time is equal to the trigger pulse width. Accordingly, longer
exposure times are supported. Additional settings determine if the trigger pulse can be accepted
during the exposure period.
Note: As the exposure time is shortened against an input trigger width, the input trigger width
should be “the necessary exposure time plus 5 μs”.
Primary settings to use this mode
Exposure Mode:
Trigger Width
Trigger Mode: ON
Trigger Option: OFF
Optical Filter Selector: 10 μs
Minimum interval of the trigger
Read out mode
Minimum trigger interval
Full
16.155 ms
ROI 1/2 (Height=1024)
8.09 ms
ROI 1/4 (Height=512)
4.077 ms
1/2V Binning (Note 1)
8.09 ms
(Note1)
GO-5000M-USB only
Trigger
CMOS
Exposure
FVAL
Exposure
Active
Exposure Period
t3
t1
t2
t1
t2
t3
10 μs (Min) 36 µs
5L
~
6L