GO-5000M-USB / GO-5000C-USB
- 32 -
8. Operating modes
8.1. Acquisition control
Acquisition control contains the following commands.
Table-14 Acquisition control command
Command
Parameter
Description
Acquisition Mode
Single Frame
One frame can be output by
AcqusitionStart command
Multi Frame
The number of frames which is specified
in Acquistion Frame Count, are output by
AcquisitionStart command
Continuous
Images are continuously output by
AcquisitionStart command until
AcqusitionStop command is input.
Acquisition Start
No(EXE command)
Start Acquisition
Acquisition Stop
No(EXE command)
Stop Acquisition
Acquisition Frame Count
1
~
255
Set the number of frames to be used in
Multi Frame mode.
Acquisition Frame Rate
0.125 to Maximum
FrameRate
Set the frame rate in fps value
Acquisition Frame Rate
Raw
8 sec to Minimum
FramePeriod
Set the frame rate in Frame period (μs)
8.1.1 Acquisition Mode
In the GO-5000-USB, the following three acquisition modes are available.
Single frame :
One frame can be output by AcqusitionStart command
Multi frames :
The number of frames which is specified in Acquistion Frame Count, are
output by AcquisitionStart command
Continuous :
Images are continuously output by AcquisitionStart command until
AcqusitionStop command is input.
8.1.1.1 Single Frame operation
In single frame mode, executing the AcquisitionStart command causes one frame to be captured.
After one frame is captured, this operation is automatically stopped.
In order to restart the capture, it is necessary to input the AcquisitionStart command again. BlockID
is not reset until AcquisitionStop is input and is incremented when the AcquisitionStart command is
called.
◆
Normal single frame operation
1) AcquisitionStart command is input
2) AcquisitionActive becomes “TRUE” (accepts capture)
3) 1 frame is output
4) AcquisitionActive becomes “FALSE” (stop capturing)