GO-5000M-USB / GO-5000C-USB
- 52 -
The above drawing shows the relationship between gain setting value (command), gain
amplitude, and dB indication. For example, the gain amplitude “x 5.62” equals 15dB.
Fig.31 Gain control
9.2.1 Gain Selector
The following parameters can be set.
GO-5000M-USB: DigitalAll
GO-5000C-USB: DigitalAll/Digital Red All/Digital Blue All
9.2.2 Gain
This is the reference value upon which gain adjustments are based. The operational adjustment is
done in Gain Raw.
GO-5000M-USB: DigitalAll
:
1
~
16 (0dB to +24dB)
GO-5000C-USB: DigitalAll
:
1
~
16 (0dB to +24dB)
Digital Red All
:
0.447
~
5.62 (0dB to +15dB)
Digital Blue All
:
0.447
~
5.62 (0dB to +15dB)
9.2.3 Gain Raw
The gain raw can be adjusted in the following range.
GO-5000M-USB: DigitalAll
:
100
~
1600
GO-5000C-USB: DigitalAll
:
100
~
1600
Digital Red All/Digital Blue All
:
-4533
~
37876
9.2.4 Gain Auto
This function automatically controls the gain level.
This is controlled by the command JAI ALC Reference.
x16
x7.15
x3.16
x1
1600
100
Gain
Amplitude
Gain
Setting
Value
Gain Control Range for
Monochrome
24dB
0dB
X89.12
X16
X7.15
X5.62
X1
X0.45
1600
0
Gain
Magnification
Gain Setting Value
(Magnification)
37876 (X5.62)
0 (X1)
-4533 (X0.45)
Gain
Setting
Value
Master
R&B
Master
Red
Blue
Gain Control Range for Bayer Color
39dB
-7dB
0dB
24dB
15dB
0dB
-7dB
15dB
0dB
-7dB
15dB
37876 (X5.62)
0 (X1)
-4533 (X0.45)