GO-5000M-USB / GO-5000C-USB
- 45 -
Primary settings to use this mode
Exposure Mode:
Timed
Trigger Mode: ON
Video Send Mode: Trigger Sequence or Command Sequence
Minimum interval of the trigger
Read out mode
Minimum trigger interval
Full
16.155 ms + Exposure time
ROI 1/2 (Height=1024)
8.09 ms + Exposure time
ROI 1/4 (Height=512)
4.077 ms + Exposure time
1/2V Binning (Note 1)
8.09 ms + Exposure time
(Note1)
GO-5000M-USB only
8.8.1.1 Trigger Sequence mode basic timing
In this mode, as each trigger input is received, the image data associated with the next
index within the preset sequence is output. In the trigger sequence mode, it is not possible to
input the trigger while the current index is executing.
The sequence index table always starts at Index 1 and changes to next index which is preset in the
Next Index setting after the current index is completed.
.
Fig. 27 Behavior of Sequence trigger
Index 1
Index 2
Index 3
Index 4
Index 5
Frame Start
Trigger In
Sequence
behavior
Frame count
=1
Next Index =
Index 2
Frame count
=1
Next Index =
Index 3
Frame count
=1
Next Index =
Index 4
Frame count
=1
Next Index =
Index 5
Frame count
=1
Next Index =
Index 6