GO-5000M-USB / GO-5000C-USB
- 33 -
◆
Forcing acquisition to stop
While AcquisitionActive is “TRUE”, if AcquisitionStop or AcquisitionAbort is
initiated, AcquisitionActive becomes “FALSE” (stop capturing).
However, if AcqusitionStop command is initiated during image output period,
AcqusitionActive becomes “FALSE” (stop capturing) after image output is completed.
Associated commands
:
Acqusition Start, Acqusition Stop
8.1.1.2 Multi Frame operation
In this mode, the AcquisitionStart command captures the number of frames which are specified by
AcquisitionFrameCount.
◆
Normal multi-frame operation
1) AcquisitionStart command is input
2) AcquisitionTriggerWait becomes effective
3) AcquisitionActive becomes
“
TRUE
”
(accepts capture)
4) Output N frames as specified by AcquisitionFrameCount
5) AcquisitionActive becomes “FALSE”. Then the output stops. (See the following
diagram)