GO-5000M-USB / GO-5000C-USB
- 63 -
EMVA 1288 Parameters
Absolute sensitivity
Maximum SNR
At 10-bit output
20.17 p (λ = 525 nm)
41.3 dB
At 10-bit output
51.25 p (λ = 525 nm)
38.12 dB
SN ratio (traditional method)
55 dB (Typical): Dark Compression
49dB (Typical): Linear
(0dB gain, Black)
50 dB
(Typical): Dark Compression
44d B(Typical): Linear
(0dB gain, Green Black)
Image
Output
format
Digital
Full pixels
2560 (h) x 2048 (v)
Bayer 2560 (h) x 2048 (v)
ROI
Width
16
~
2560, 16 pixels/step
16
~
2560, 16 pixels/step
OFFSET X
0
~
2544, 16 pixels/step
0
~
2544, 16 pixels/step
Height
1
~
2048 lines,1 line/step
2
~
2048 lines,2 line/step
OFFSET Y
0
~
2047 lines, 1 line/step
0
~
2046 lines, 2 line/step
Binning
H
1
2560 (H)
2560 (H)
2
1280 (H)
-
4
640 (H)
-
V
1
2048 (V)
2048 (V)
2
1024 (V)
-
4
512 (V)
-
Bit assignment
Mono8, Mono10, Mono12
Mono10Packed, Mono12Packed
BayerGR, BayerGR10, BayerGR12
BayerGR10Packed, BayerGR12Packed
Acquisition mode
Continuous / Single Frame / Multi Frame (1
~
255)
Trigger Selector
Acquisition
Acquisition Start/ Acquisition Stop
Exposure
Frame Start
Transfer
Acqusition Frame Transfer
Trigger option
OFF / RCT (with ALC function)
Trigger Overlap
Fixed to Readout
Trigger Input Signal
Line 5 (Opt In), Software, PG 0, NAND Out 0/1, User out 0/1
Opto In Filter
5 steps: 10μs (Typ), 100μs, 500μs, 1ms, 5ms, 10ms
Exposure mode
OFF, Continuous, Timed (EPS), Trigger Width
Exposure
Mode
Timed
Exposure Auto: OFF 10 μs (Min.)
~
8 second (Max.Note1),
Variable unit: 1
μs
Exposure Auto: Continuous 10 µs (Min.)
~
8 second (Max.Note1),
Variable unit: 1 μs
Trigger Width
10 μs (Min.)
~
∞
(Max. Note1)
Exposure Auto
OFF / Continuous
Auto Exposure Response Speed
1
~
8
Video send Mode
Normal ROI, Multi ROI, Trigger Sequence, Command Sequence,
Delayed readout
Digital I/O
Line Selector (6P): GPIO IN / GPIO OUT
Black
Level
Adjust.
Ref. level
33.5LSB 10-bit (Average value of 100*100)
Video Level adj. range
0
~
approx. 100LSB
Adj. range
-256
~
+255LSB 10-bit
Resolution
1 STEP = 0.25LSB
Analog Base Gain (For manual only)
0dB, 6dB, 12dB
0dB, 6dB, 12dB (R/G/B individual
setting)
Gain
Control
Manual
Adj. range
-0dB
~
+24dB (Note2)
1 step=x0.01 (0.005dB to 0.08dB)
Varies by setting value
-0dB
~
+24dB (Note2)
1 step=x0.01 (0.005dB to 0.08dB)
Varies by setting value