GO-5000M-USB / GO-5000C-USB
- 39 -
8.3.1 Trigger Selector
Selects the trigger operation. In the GO-5000-USB, the following trigger operation can be
selected as the trigger.
Table – 19 Trigger selector
Each trigger selection has its own settings. Therefore, it is necessary to set up the following items
on each selected trigger.
Trigger Mode
Trigger Source
Trigger Activation
8.3.2 Trigger Mode
Select either free-running operation or external trigger operation.
OFF:
Free-running operation
ON:
External trigger operation
8.3.3 Trigger Source
The following signals can be used as the trigger source signal.
Table – 20 Trigger source
8.3.4 Trigger activation
This command can select how to activate the trigger.
Trigger Selector Item
Description
Acquisition Start
Set to start Acquisition or not
Acquisition End
Set to end Acquisition or not
Frame Start
Set to start Frame control or not
Acquisition Transfer Start
Set to start the stream or not
Trigger Source
item
Description
Low
Connect LOW level signal to the selected trigger operation
Default setting
High
Connect HIGH level signal to the selected trigger operation
Soft Trigger
Connect Soft Trigger signal to the selected trigger operation
Trigger can be input manually by the execution of the software trigger
Trigger software is available on each trigger source.
PulseGenerator0
Out
Connect Pulse Generator 0 signal to the selected trigger operation
User Output 0
Connect User Output 0 signal to the selected trigger operation
User Output 1
Connect User Output 1 signal to the selected trigger operation
Line 5 - OPT IN
Connect OPTO IN 1 signal to the selected trigger operation
NAND 0 Out
Connect NAND 0 OUT signal to the selected trigger operation
NAND 1 Out
Connect NAND 1 OUT signal to the selected trigger operation