![background image](http://html1.mh-extra.com/html/jacto/advance-2000-am-18/advance-2000-am-18_operators-manual_3177642098.webp)
5-98
5
M
A
INTE
NAN
CE
ADVANCE 2000
Table 12: Intermittence
Table 11: Oscillation in pressure
Probable causes
Indications and corrections
1. Entry of air into the inlet system.
Caused by a hole in the hose, damaged filter sealing
ring, etc.
Check and repair any leaks if there are.
2. Pressure regulator.
Check the valve and valve seat to ensure yourself
that these components are correctly adjusted
Probable causes
Indications and corrections
1. Tap closed.
Due to the design of the 3 way valve, even when it is
in the closed position there will still be liquid flow
-
ing when the pump operates, therefore there will be
insufficient flow.
2. Poor operation of the agricultural
chemical pump.
Valve not sealing correctly due to impurities or jamming.
3. The pump head is internally damaged. Replace the head of the agricultural chemical pump.
Problems, causes and corrections