Capter3
Function
Setting and Basic Operation
Curve Tracer CS-5000 Series Instruction Manual
3-41
For example, if the source of the horizontal axis range is set to COLLECTOR and "Ic" is selected for the
1st waveform on VIEW MODE = WAVE screen, the vertical range and that of the waveform on the 1st
side of WAVE move together.
For WAVE screen
For WAVE screen, actions of the vertical axis range and the horizontal axis range are as follows:
- For the vertical axis range, the source always moves together in other case than STEP.
- For the horizontal axis range, the waveform moving together changes (Vbe/Vce) depending on the source
of COLLECTOR or BASE-EMITTER.
Ranges move together