54
Troubleshooting
Troubleshooting
First check the following points. If the following measures do not help remove problems, con-
tact your nearest distributor.
■
Pump
States
Possible causes
Solutions
The pump does not run
( The operation LED
does not light or the
screen is blank.).
Power voltage is too low.
• Observe the allowable voltage range of
90-264VAC.
The pump is not powered.
• Check the pump is switched on.
• Correct wiring.
• Replace a breaking wire to new one.
Liquid can not be
pumped up.
Air lock in the pump
• Expel air. See page 33.
Air ingress through a suction line
• Reroute piping.
An O ring is not
fi
tted to a valve set.
• Fit O ring to the valve set.
Foreign matters are stuck in the pump
head valves.
• Dismantle, inspect and clean the valves.
Replace as necessary.
A ball valve is stuck on a valve seat.
• Dismantle, inspect and clean the valve.
Replace as necessary.
A vale seat has been pressed in the
valve guide.
• Do not push the valve seat into the valve
guide. See page 59.
A
fl
ow rate
fl
uctuates.
Air stays in the pump head.
• Expel air. See page 33.
Overfeeding occurs.
• Mount a back pressure valve to keep a
constant level of discharge line pressure.
Foreign matters are stuck in the pump
head valves.
• Dismantle, inspect and clean the valves.
Replace as necessary.
Diaphragm is broken.
• Replace the diaphragm. See page 59.
Pressure
fl
uctuates at an injection
point.
• Maintain a pressure constant at an injec-
tion point by optimizing piping or by relo-
cating the point.
Liquid leaks.
A
fi
tting is loose.
• Tighten the nut to
fi
x the
fi
tting.
Loose
fi
t of the pump head
• Retighten the pump head. See page 32.
An O ring is not
fi
tted to a valve set.
• Fit O ring to the valve set. See page 58.
Diaphragm is broken.
A leak from the drain port (Vent hole)
• Replace the diaphragm. See page 59.