50
Operation
Read this section before operation.
Manual operation
Run or stop the pump by keypad operation.
Supply the rated power voltage to the pump.
The operation LED lights in red colour, and a previous mode at the last shutoff returns.
* The pump enters the MAN/EXT selection mode when turning on power with a default setting.
Push the ESC key to enter MAN/EXT selection mode.
Push the start/stop key to stop operation if the IX is running.
Push the left key to select "MAN" and the Enter key to enter that choice.
The pump enters a waiting state. Use the UP and DOWN keys to set a
fl
ow rate.
Push the start/stop key to start operation.
The operation LED lights in green colour during operation.
EXT operation
The pump operation is controlled by the external signal.
Supply the rated power voltage to the pump.
The operation LED lights in red colour, and a previous mode at the last shutoff returns.
* The pump enters the MAN/EXT selection mode when turning on power with a default setting.
Push the ESC key to enter MAN/EXT selection mode.
Push the start/stop key to stop operation if the IX is running.
Operation