26
Drain port (Vent hole)
Leaked liquid drains through a drain port at the time of accidental diaphragm rupture.
Use a chemically-resistant tube to the drain port to collect the liquid in a tank.
NOTE
• Do not plug the drain port. The port functions as a vent hole to keep the pressure in the pump head constant.
• Do not immerse the tube end in liquid, or liquid may be pumped up through the drain port in operation.
(ø
6)
(ø
7.5)
(20)
Drain port (vent hole)
*Applicable tube size
Inner diameter: 6mm
Outer diameter: 12mm or below
Drain port (Vent hole)
Empty drain tank
Do not place the drain tube
end below a liquid level.
Do not suck up fumes from
corrosive chemicals such as
sodium hypochlorite.
Noncorrosive chemicals in a
supply tank. The drain tube end
must stay above a liquid level.