36
Start calibration operation.
Push the Enter key after setting the number of
strokes. The pump starts a countdown.
The pump starts to run for the set number of
strokes as it comes to zero.
Measure liquid volume in the calibration cylinder again.
Enter how much liquid has reduced.
Use the UP and DOWN keys to set the volume reduction.
Push the Enter key once. The screen shows
fl
ow volume
per shot. Calibration now has been completed.
* The screen shows "ERROR! Volume Out Of Range!!" if the
reduction is too little or too large. Enter correct liquid volume or
recalibrate it.
NOTE
Calibration with high viscosity liquid at a full suction speed
will often give rise to this error. Reduce a suction speed
along with viscosity.
Push the ESC key to return to the wait mode.
Pump
stops
5
6
Pump
starts
7
Perform a calibration