10
Precautions for use
Precautions for use
• Electrical work should be performed by a quali
fi
ed operator. Otherwise,
personal injury or property damage accident may result.
• Do not install the pump in the following places where...
–Under a
fl
ammable atmosphere or in a dusty/humid place.
–Under direct sunlight or wind & rain.
– Ambient temperature exceeds 50ºC or falls below 0ºC.
• Select a level location where is free from vibration and liquid can't stay.
Anchor the pump with four M8 bolts so as not to vibrate. If the pump is
installed at a tilt, a
fl
ow may reduce.
• When two or more pumps are installed, the pump operation interacts each
other and vibration becomes significant, resulting in poor performance or
failure of internal electrical devices. Select an installation location where
tolerates vibration to enough degree.
• Keep an ample working area around the pump for inspection and mainte-
nance.
• Install the pump as close to a supply tank as possible.
• Install the pump in a cool and dark place when handling liquids that readily
generate gas bubbles such as sodium hypochlorite or hydrazine solution.
Flooded suction application is strongly recommended for these liquids.
• A suction line bore should be wider than the inlet bore of the pump.
• Build up a flooded suction system for the viscous liquid delivery of
300mPa•S or more.