Do not use the pump in a wet location
The pump is not waterproof. Use of the pump in wet or extremely humid
locations could lead to electric shock or short circuit.
Grounding
Risk of electrical shock! Always properly ground the pump. Conform to lo-
cal electric codes.
Install a GFCI (earth leakage breaker)
An electrical failure of the pump may adversely affect other devices on the
same line. Purchase and install an earth leakage breaker separately.
Preventative maintenance
Follow instructions in this manual for replacement of wear parts. Do not
disassemble the pump beyond the extent of the instructions.
Do not use a damaged pump
Using a damaged pump could lead to an electric leak or shock.
Disposal of a used pump
Dispose of any used or damaged pump in accordance with local rules
and regulations. If necessary, consult a licensed industrial waste disposal
company.
Check the pump head bolts
Liquid may leak if any of pump head bolts become loose. Tighten the bolts
evenly to the specified torque below in diagonal order before initial opera-
tion and at regular intervals.
Tightening torque
EHN-B11/-B16/-B21/-C16/-C21 : 2.16 N•m
EHN-B31/-C31/-C36
: 2.55 N•m
Install a relief valve
Install a relief valve on a discharge line near the pump so as to automati-
cally release the discharge pressure when it exceeds the maximum level.
Requirement
Requirement
Caution
Electrical
shock
CAUTIONS
Requirement
Prohibited
Grounding
Prohibited