Before operation
■ Stroke rate adjustment
The stroke rate can be set by keypad operation from 1 to 360spm. The relation between the flow rate* and the
stroke rate is shown as below.
Turn on power and call up manual mode.
Use the UP or DOWN key to adjust a stroke rate.
• spm increases/decreases as pushing the UP/DOWN keys.
• Press and hold either key for three seconds for quick change. Quick change stops at 1 or 360spm. 1 or
360rpm skips to 360 or 1spm when the key is released and pushed once.
Push the start/stop key.
The ON LED blinks at each shot during operation.
*
100% discharge capacity equals to the
flow rate described on the nameplate.
1
2
3
Fixed stroke length
100
%
75
50
25
0
180
360
spm
D
is
c
har
g
e
c
apa
c
it
y
Stroke rate adjustment