26
Check valve
Accumulator/Chamber
Check valve
Accumulator/Chamber
Pump
Pump
Air vent valve
Relief valve
Relief valve
Air vent valve
1
Plumbing
O.D.9mm
R1/2
R3/8
Mount a check valve at the discharge tube end.
*
The CAN check valve has the R1/2 and R3/8 thread connections as well as an O.D. 9mm tube connection. Cut off
an unused part and adjust the connection length as necessary.
CA check valve
*
The CBN check valve (both ends tube connections) and the BVC back pressure valve are optionally available.
Contact us or your nearest distributor.
CBN check valve
BVC back pressure valve
NOTE
• Periodically clean or replace a check valve with new one for the prevention of crystal clogging, especially
when using sodium hypochlorite.
• In the nature of the pump, the lower discharge pressure, the higher discharge capacity (and vice versa). If you
want to observe the max discharge capacity at any low level of system (/discharge) pressure, use the check/
back pressure valve to give the additional pressure of 0.17MPa±0.04 to the discharge line or reduce the pump
speed/stroke length.
Tubing layout
Flooded suction application
Suction lift application
*
Flooded suction installation is strongly recommended when handling liquids that generate gas bubbles (sodium hypochlo-
rite or hydrazine solution).
O.D.12mm
R1/2
R3/8
Summary of Contents for EHN-B11-NAE