12
Overview
Introduction
Pump characteristics, features and part names are described in this sec-
tion.
Introduction
Pump structure & Operating principle
The EHN series is a diaphragm metering pump which consists of a pump head, drive unit and control unit. A
diaphragm is directly driven by electromagnetic force.
Principle of operation
Electromagnetic force and spring force make reciprocating motion. The reciprocating motion is transferred to a
diaphragm through a plunger and then volumetric change occurs in the pump head. This action transfers liquid
along with pump head valve action.
Control unit
Pump head
Drive unit
Spring
Pump head valve
(Discharge side)
Pump head valve
(Suction side)
Plunger
Diaphragm
Stroke length
adjusting knob
OUT
IN
Summary of Contents for EHN-B11-NAE