Operation Manual – ITW GSE 6400 Tier 4
d) Check
Radiator
Core
and
Hoses.
i.
Inspect the radiator core for dirt and debris blocking the fins. Clean as necessary.
Check for cracks, holes, or other damage.
ii. Check
Fuel
Pump.
iii. Inspect
the
fuel
injection
pump
mounting nuts for loose or damaged hardware.
2) Electrical
(12 VDC System)
.
NOTE:
The battery furnished with this generator set is MAINTENANCE FREE. Check battery
terminals and clean if necessary.
a) Check the battery terminals and clean if necessary.
f) “C” Checks and Operations (500 Hours or 6 Months)
1) Engine.
a) Check Engine and Generator Mounts
CAUTION
An unstable or loosely mounted engine can create hazardous environment and may
damage equipment.
i.
Engine mount bolts must be torqued to 100 N-m (73.7 ft-lb.).
ii.
Generator mount bolts must be torqued to 100 N-m (73.7 ft-lb.).
b) Change
oil
and
oil
filters.
c) Change
all
fuel
filters.
d) Check
Coolant
Additive
Concentration.
The cooling system protective liquid (nitrite-, amine- and phosphate free) provides
effective protection against corrosion, cavitation, and freezing. See engine
manufacturer’s operation manual for ordering and mixture details.
2) Electrical
(12 VDC system)
.
3) Wiring.
a) Inspect all cables and leads for worn or damaged insulation.
b) Connections.
i.
Inspect connectors for damaged or corroded condition.
OM2248 Rev B