1
2
3
4
1.
Rear coupling guard half
2.
Annular groove
3.
Deflector fan guard
4.
Driver
Figure 27: Rear coupling-guard half installation
Locate the opening (flange) so that it does not interfere with the piping but does allow access for
installing the bolts.
1
2
3
1.
Annular groove
2.
Deflector fan guard
3.
Coupling guard half
Figure 28: Opening (flange) location
5.
Place one washer over the bolt and insert the bolt through the round hole at the front end of the
guard half.
6.
Place a second washer over the exposed end of the bolt and tighten it firmly.
7.
Thread a nut onto the exposed end of the bolt and tighten it firmly.
This figure shows the proper sequence of components:
5.4 Couple the pump and driver
48
Model 3700, 3703, 3710, 3700LF, 3700LFI API Type OH2 / ISO 13709 1st and 2nd Ed. / API 610 8/9/10/11th Ed. Instal-
lation, Operation, and Maintenance Manual
Summary of Contents for Goulds Pumps 3700