11. Firmly tighten all nuts on the guard assembly.
5.4.1.2 Install the coupling guard with the optional air cooling package
1.
Is the deflector-fan guard support installed?
•
If yes: Make any necessary coupling adjustments and then proceed to step 2.
•
If no: Complete the following steps:
a) Remove the spacer portion of the coupling.
Refer to the coupling manufacturer's instructions.
b) If the coupling hub diameter is larger than the diameter of the opening in the deflector-fan
guard support, then remove the coupling hub.
c)
Loosen the thrust deflector-fan set screw.
122 Shaft
123B Radial deflector fan
123E Thrust deflector fan
222 Deflector set screw
228 Bearing frame
234 Thrust deflector-fan guard
234D Thrust deflector-fan guard support
496Q Support screws
Figure 25: Coupling guard with optional air cooling package
d) Slide the thrust deflector fan off of the shaft.
5.4 Couple the pump and driver
46
Model 3700, 3703, 3710, 3700LF, 3700LFI API Type OH2 / ISO 13709 1st and 2nd Ed. / API 610 8/9/10/11th Ed. Instal-
lation, Operation, and Maintenance Manual
Summary of Contents for Goulds Pumps 3700