Example: Elbow close to the pump suction inlet
Correct
Incorrect
The correct distance between the inlet flange of the
pump and the closest elbow must be at least five pipe di-
ameters.
Example: Suction piping equipment
Correct
Incorrect
1
2
3
4
5
1.
Suction pipe sloping upwards from liquid source
2.
Long-radius elbow
3.
Strainer
4.
Foot valve
5.
Eccentric reducer with a level top
1
1.
Air pocket, because the eccentric reducer is not
used and because the suction piping does not
slope gradually upward from the liquid source
4.6 Piping checklists
34
Model 3700, 3703, 3710, 3700LF, 3700LFI API Type OH2 / ISO 13709 1st and 2nd Ed. / API 610 8/9/10/11th Ed. Instal-
lation, Operation, and Maintenance Manual