184 Seal-chamber cover
412S Outer water-jacket-cover O-ring
490 Water jacket cover
497T Outer and inner water-jacket-cover O-ring
Figure 72: Optional water jacket cover
2.
Lubricate the sealing surfaces in the seal-chamber cover and O-rings with a suitable lubricant.
3.
Insert the water jacket cover with O-rings into the fit in the seal-chamber cover.
Make sure that the water jacket cover enters uniformly and that the O-rings are not damaged.
6.6.4 Install the seal-chamber cover
1.
Install the eyebolt in the tapped hole provided in the seal-chamber cover.
6.6 Reassembly
Model 3700, 3703, 3710, 3700LF, 3700LFI API Type OH2 / ISO 13709 1st and 2nd Ed. / API 610 8/9/10/11th Ed. Instal-
lation, Operation, and Maintenance Manual