6.4.6 Remove the impeller (3700/3710)
CAUTION:
Risk of physical injury from sharp edges. Wear heavy work gloves when handling impellers.
1.
Loosen the set screw at the end of the impeller nut.
2.
Loosen and remove the impeller nut.
The impeller nut has left-hand threads.
122 Shaft
198A Set screw
304 Impeller nut
3.
Pull the impeller from the shaft.
Use a spanning-type puller if required.
4.
Remove the impeller key.
Save the key for reassembly unless it is damaged.
6.4.7 Remove the impeller (3703)
CAUTION:
Risk of physical injury from sharp edges. Wear heavy work gloves when handling impellers.
1.
Loosen the set screw at the end of the impeller nut.
2.
Loosen and remove the impeller nut.
The impeller nut has left-hand threads.
6.4 Disassembly
68
Model 3700, 3703, 3710, 3700LF, 3700LFI API Type OH2 / ISO 13709 1st and 2nd Ed. / API 610 8/9/10/11th Ed. Instal-
lation, Operation, and Maintenance Manual
Summary of Contents for Goulds Pumps 3700