Check
Procedure
Shaft
impel-
ler fit
1.
Mount the dial indicator on the bearing frame.
2.
Rotate the shaft through a maximum arc from one side of the keyway to the other. If the
total indicator reading is greater than 0.050 mm | 0.002 in., determine the cause and correct
it.
Shaft
seal fit
1.
Mount the dial indicator.
2.
Rotate the shaft so that the indicator rides along the shaft surface for 360°. If the total indi-
cator reading is greater than 0.050 mm | 0.002 in., then determine the cause and correct it.
Bear-
ing-
frame
face
1.
Mount the dial indicator on the shaft.
2.
Rotate the shaft so that the indicator rides along the bearing-frame face for 360°. If the total
indicator reading is greater than 0.10 mm | 0.004 in., then disassemble and determine the
cause and correct it.
6.6 Reassembly
Model 3700, 3703, 3710, 3700LF, 3700LFI API Type OH2 / ISO 13709 1st and 2nd Ed. / API 610 8/9/10/11th Ed. Instal-
lation, Operation, and Maintenance Manual
101
Summary of Contents for Goulds Pumps 3700
Page 2: ......