122 Shaft
184 Seal-chamber cover
228 Bearing frame
230 Seal-chamber cover wear-ring
370H Bearing-frame bolts
Figure 73: Seal chamber cover
2.
Set up a sling from the eyebolt to the overhead lifting device.
3.
Lift the seal-chamber cover and position it so that it aligns with the shaft.
4.
Install the seal-chamber cover on the bearing-frame assembly:
a) Guide the cover carefully over the shaft and into the bearing-frame lock.
b) Install the seal-chamber cover and bearing-frame bolts.
c)
Tighten the bolts evenly using an alternating pattern.
Torque the bolts to values shown in the Maximum torque values for 3700 fasteners table.
5.
Check the seal-chamber cover face runout:
a) Mount the dial indicator on the shaft.
b) Rotate the shaft so that the indicator rides along the seal-chamber cover face for 360°.
If the total indicator reading is greater than 0.13 mm | 0.005 in., determine the cause and correct it.
6.6 Reassembly
104 Model 3700, 3703, 3710, 3700LF, 3700LFI API Type OH2 / ISO 13709 1st and 2nd Ed. / API 610 8/9/10/11th Ed. Instal-
lation, Operation, and Maintenance Manual
Summary of Contents for Goulds Pumps 3700