23 of 36
REGLO ICC - ENGLISH , REV. D, 14-036-E
Ref. #
Command
Function
Op
Response
3.0
OPERATIONAL MODES AND SETTINGS
3.15
v
Get the current setting for volume in mL.
Get
Volume Type 1
3.16
v
Set the current setting for volume in mL. Volume Type 2.
Set
Volume Type 1
3.17
xT
Get the current pump run time.
Get
Time Type 1
3.18
xT
Set current pump run time using Time Type 2.
Set
*
3.19
xP
Get pumping pause time.
Get
Time Type 1
3.20
xP
Set pumping pause time using Time Type 2.
Set
*
3.21
“
Get pump cycle count.
Get
Discrete Type 1
3.22
“
Set pump cycle count Discrete Type 2.
Set
*
3.23
?
Max flow rate achievable with current settings mL/min.
Get
Text
3.24
!
Max flow rate achievable with current settings using calibration.
Get
Text
3.25
xv
Get time to dispense at a given volume at a given mL/min flow rate.
Vol, Volume Type 2; flow rate, Volume Type 2.
Get
Time Type 1 (0.1 sec)
3.26
xw
Get time to dispense at a given volume at a given RPM. mL,
Volume Type 2; flow rate, Discrete Type 3.
Get
Time Type 1 (0.1 sec)
4.0
CONFIGURATION
4.1
+
Get the current tubing inside diameter in mm. 2 decimal places
are returned.
Get
4 characters including decimal (mm).
4.2
+
Set tubing inside diameter using Discrete Type 2.
Set
*
4.3
%
Get the current backsteps setting.
Get
Discrete Type 1
4.4
%
Set the current backsteps setting using Discrete Type 2.
Set
*
4.5
0
Resets all user configurable data to default values.
Set
*
5.0
CALIBRATION
5.1
xR
Get direction flow for calibration.
Get
DIRECTION, J = CW K = CCW
5.2
xR
Set direction flow for calibration J or K using DIRECTION format.
Set
*
5.3
xU
Get the target volume to pump for calibrating, mL.
Get
Volume Type 1
5.4
xU
Set the target volume to pump for calibrating using Volume Type 2.
Set
Volume Type 1
5.5
xV
Set actual volume measured during calibration, mL Volume Type 2.
Set
Volume Type 1
5.6
xW
Get the current calibration time.
Get
Time Type 1
5.7
xW
Set the current calibration time using Time Type 2.
Set
*
5.8
xX
Get the channel run time since last calibration.
Get
Time Type 2
5.9
xY
Start calibration on a channel(s).
Set
*
5.10
xZ
Cancel calibration.
Set
*
6.0
SYSTEM
6.1
(
Returns the
pump firmware version
.
Get
Discrete Type 2
6.2
xt
Change factory roller step volume for a particular roller count and
tubing size using roller count (6,8,12), Discrete Type 1; index of the
tubing diameter (see Table 1), Discrete Type 1; RSV. Volume Type 2.
Set
*
6.3
xs
Save set roller step settings.
Set
*
6.4
xu
Reset roller step volume table to defaults.
Set
*
6.5
xN
Set pump name for display under remote control–String.
Set
*
6.6
xS
Get pump serial number.
Get
String
6.7
xS
Set pump serial number–String.
Set
*
6.8
xL
Get the current pump language.
Get
Language
6.9
xL
Set current pump language–Language.
Set
*
6.10
xA
Get number of pump channels.
Get
Discrete Type 1
6.11
xA
Configure number of pump channels. Discrete Type 2.
Set
*
6.12
xB
Get number of rollers for channel.
Get
Discrete Type 1