54
Uni-3 Technical Manual
3.15 B18-Error Process
Configure the scale’s response for specific error conditions.
B17-12
Subtotal
B17-12-01 Pack Run Total
Select if the accumulated Run Total is cleared
automatically or manually.
1: BUZZER – Subtotal is not cleared even when an item
is called during the production under
Target Pack
Count
mode.
2: BUZ+CLR – Subtotal is cleared when the first label
printing is completed after an item is called during the
Target Pack Count
mode.
1: BUZZER
2: BUZ+CLR
B17-12-02 Subtotal Count
Select how many subtotal labels are issued when the
key is pressed.
1: 1
2: 2
Parameter
Display
Description
Choices
B18-01
Issue
B18-01-01 Zero Price
Select the response when the total price is zero.
1: Print zero price in the barcode and do not print the total price
2: Do not print the barcode and the total price prints as “$0.00”
3: Do not print the barcode or total price.
1: BAR 0
2: NO.BAR
3: NO PRICE
B18-01-02 Error Tare
Select if an error message is displayed when the tare weight is set
as zero (0284-0000).
1: NO
2: YES
B18-01-03 Error Zero Price
Select if an error message is displayed when the total price is
zero.
1: NO
2: YES
B18-02
Call
B18-02-01 No POS Error
Select the response when the barcode identifying the product is
zero:
1: No error
2: Display an error and do not print the label (0342-0000)
3: Display an error and do not print the barcode (0343-0000)
1: NO DISP
2: NO PRINT
3: NO BAR
B18-02-02 Tare Cancel Error
Not applicable for USA.
0: YES
1: NO
B18-02-03 – B18-05
Extra Message 1 - Message 3
Display Error
Select if an error is displayed when the extra message assigned to
the PLU does not exist.
Extra Message 1 – 0275-0000
Extra Message 2 – 0276-0000
Extra Message 3 – 0277-0000
1: NO
2: YES
B18-02-06 Coupon Message
Display Error
Select if an error is displayed when the coupon message
assigned to the PLU does not exist. 0223-0000
1: NO
2: YES
B18-03
Common
B18-03-01 Damaged
Thermal Error
Select the response when the thermal head has a damaged print
element:
1: Display an error message that can be cleared
2: Display an error message that cannot be cleared
3: Do not display any error message
1: ONE TIME
2: CONTI
3: NO MESG
Table 3-15. B18 Error Process Parameters
Parameter
Display
Description
Choices
Table 3-14. B17 Operation Setting Parameters (Continued)