64
Uni-3 Technical Manual
4.0
Adjustment Mode
4.1
Enter Adjustment Mode
Enter
4000
and press
Mode
to enter the Adjustment mode menu. To exit the Adjustment mode, press
Mode
.
Many functions in the Adjustment mode are restricted to authorized service personnel. Enter the service
password 495344 and press PLU to access all Adjustment mode functions. All Adjustment mode functions are
available until the scale returns to normal operation mode.
Adjustment Mode Main Menu Screen
The Adjustment Mode for this device includes the following parameters:
*Full access requires the service password.
Use the
Up
and
Down
arrow keys to select a parameter within the Adjustment menu. Press the
Enter
key to enter the
parameter. Use the
Up
and
Down
arrow keys to move through the menu options. Use the
Left
and
Right
arrow keys
(or key in the corresponding number) to select the appropriate choice.
Example:
1. From the Adjustment mode main menu screen, press the
Down
arrow several times to scroll to
C11 OPTION CHECK
.
2. Press
Enter
to enter
C11 OPTION CHECK
.
3. Press
Enter
to enter the parameter
C11-01 SCANNER CHECK
.
4. Use the
Down
arrow key to scroll to
C11-01-02 SCANNER
SELECT
.
5. Press the
Right
arrow key to view the available options
from
1: NONE
to
3: UART
To change the current setting, enter the numeric value,
example 2, then press
Enter
to select
2:USB
.
6. Press
Mode
to return to the main step
C11 OPTION CHECK
.
7. Exit the setup mode by pressing
Mode
.
Note
< COO ADJUST >
&22$'-867`
1. Date Time
3. Display Check
4. Key Check*
5. Firmware Details
6. Memory Clear*
7. Printer*
8. Calibration*
10. Download*
11. Option Check*
13. Model*
C11 OPTION CHECK
&237,21&+(&.
< SCANNER CHK > [ENT]
&>6&$11(5&+.@
*SCANNER SEL 1:NONE
FVFDQQHUVHO
*SCANNER SEL 2:USB
FVFDQQHUVHO