Position the Panel PC so that the air vents in the housing are not
back covered by following installation.
The max. air intake temperature must not exceed the max. operative
temperature provided for the Panel PC in use. Moreover the input air
must be free of corrosive gas or powder.
The Panel PC weigh is indicated in “Mechanical specification”. Verify
that the addition of the Panel PC does not cause instability of the
cabinet.
Install the Panel PC in a way it doesn’t cause a potentially hazardous
situation (e.g. falling down).
If required use stiffeners to reinforce the cut-out mounting.
Leave enough free room for disassemble and maintenance service
Avoid condensation inside the cabinet
The Panel PC is set up for installation in a prepared recess such as in the panel of
a cabinet or a console, so that the only part accessible to the operator is the front
panel, including the touchscreen (option) and the LCD. This is the use for which it
is designed.
Place the screen in an ergonomic position for the operator and select a
corresponding installation height.
The maximum panel thickness allowed is 5mm. The minimum suggested is 2mm.
4.1 Permitted mounting positions
The Panel PC is designed to be installed in vertical position only with a +45° / -5°
deviation in the direction indicated.
+ -