7.1.2 Advanced Configuration
Click Start
→
Settings
→
Record
→
Advanced to go to the following interface. Enable or disable cycle
record (cycle record: the earliest record data will be replaced by the latest when the disks are full).
Choose the record stream. Set the pre-alarm record time, post-alarm record time and expiration time
of each camera and then click “Apply” to save the settings.
Pre-alarm Record Time:
set the time to record before the actual recording begins. Post-alarm
Record Time:
set the time to record after the actual recording is finished.
Expiration Time:
set the expiration time for recorded video. If the set date is overdue, the recorded
data will be deleted automatically.
7.2 Encode Parameters Setting
Click Start
→
Settings
→
Record
→
Encode Parameters to go to the interface as shown below. Set the
encode, resolution, FPS, GOP, bitrate type, quality, max bitrate and audio of main stream for each
camera in
“
Event Recording Settings
”
and
“
Schedule Recording Settings” interfaces. Click
“Apply” to save the settings. You can set the record stream of each camera one by one or set them in
bulk for all cameras.
Click Start
→
Settings
→
Record
→
Stream Settings to go to
“
Sub-stream
”
interface. Set the
encode, resolution, FPS, GOP, bitrate type, quality and max bitrate of sub-stream for each camera in
the interface and then click
“
Apply
”