28
OPERATION AND SET-UP ON THE CONTROLLER
inVENTer Connect controller platform | Operating instructions
Ending device pairing
The system exits the device pairing state when:
• the maximum number of paired devices is reached (max. 16),
• the time is exceeded,
• or a corresponding key entry is made.
Termination by key entry
Requirements:
• All components relevant to the ventilation system
are paired.
• The display screen shows the number of paired
components.
►
Press the mode key to confirm the paired
components.
The display screen shows the information that the
paired system components (inner covers, external
sensors, switching contact) send to the controller.
The system operates in the default profile (factory
settings).
If not already done, the closing flap must be
reattached to the inner cover at this point. See
Page 26; Swivelling the locking arm to the right.
Start screen: System information
After all inner covers (ventilation units) and sensors have been paired with the controller and the
pairing of the components has been confirmed, the ventilation systems starts with the factory
settings, i.e.:
• all ventilation units and sensors are assigned to ventilation zone 1.
•
the predefined ventilation profile for ventilation zone 1 is set (default profile).
In the factory-set default profile, the system operates at 25 % fan speed and in heat recovery
mode.
It is possible to define up to four ventilation zones. Different ventilation units, sensors and profiles
can be assigned to the individual ventilation zones.
Please note: additional ventilation zones can only be set up via the app (
4: Operation and
set-up with the app).