Chapter 5: Advanced setup
68
TruVision DVR 10 User Manual
enter the number for the PTZ preset to be used. See “PTZ settings” on page
74 for more information on defining PTZ presets.
Note:
Make sure that the PTZ you are using can support preset, preset tour,
and shadow tour functions. An external alarm input can trigger a camera’s
PTZ linkage.
9. Click Confirm to save and return to the Alarms screen.
10. To copy the alarm input parameters to another alarm input, select the new
alarm input from the Copy to Alarm In list box, and then click Copy.
11. Click Confirm on the Alarms screen to save your changes and return to the
main menu.
To set up an alarm relay output:
1. Select an alarm output in the Alarm Out box.
2. Select the alarm output duration.
The alarm output duration is the length of time that an alarm output displays
before stopping. Options include: 5, 10, and 30 seconds, 1,2, 5, and 10
minutes, and Manual Stop. Manual Stop indicates the alarm output will not
stop until you specify Stop in the Alarm Output option on the Utilities screen.
See “Acknowledging an alarm” on page 84 for more information.
3. Define an alarm out schedule.
Click Alarm Out Time Schedule on the Alarms screen to enter the AlarmOut
schedule as shown in the figure below. Select the day of the week and under
Period 1 and enter the start and end time periods for the selected day. Each
day can have up to four time periods.
Repeat for each day of the week. If the desired times for this alarm output are
identical to those for other days, click Copy To and specify the day of the