32
S30-1SLC/A-60
SFP-Port 1000Base-BX GBIC module - 60KM 0~50•C
S30-1SLC/B-60
SFP-Port 1000Base-BX GBIC module - 60KM 0~50•C
10Gigabit Ethernet Transceiver (10GBase-X SFP+)
S40-2MLC
SFP-Port 1G Base-SX Transceiver – 300M 0~50•C
S40-2SLC-10
SFP-Port 1G Base-SX Transceiver - 10KM 0~50•C
1. It is recommended to use Interlogix SFP on the Managed Switch. If you insert an SFP transceiver
that is not supported, the Managed Switch will not recognize it.
2. Port 21 to Port 24 are a shared SFP slot that supports the Gigabit and Fast Ethernet SFP
transceiver.
3. Port 25 to Port 28 are a shared SFP+ slot that supports the 10 Gigabit SFP+ transceiver and
Gigabit SFP transceiver.
1.
Before we connect the NS4702-24P-4S-4X to the other network device, we have to make sure both sides of the SFP
transceivers are with the same media type, for example: 1000Base-SX to 1000Base-SX, 1000Bas-LX to 1000Base-LX.
2.
Check whether the fiber-optic cable type matches with the SFP transceiver requirement.
To connect to 1000Base-SX SFP transceiver, please use the multi-mode fiber cable with one side being the male duplex
LC connector type.
To connect to 1000Base-LX SFP transceiver, please use the single-mode fiber cable with one side being the male duplex
LC connector type.
Connect the Fiber Cable
1.
Insert the duplex LC connector into the SFP/SFP+ transceiver.
2.
Connect the other end of the cable to a device with SFP/SFP+ transceiver installed.
3.
Check the LNK/ACT LED of the SFP/SFP+ slot on the front of the Managed Switch. Ensure that the SFP/SFP+ transceiver is
operating correctly.
4.
Check the Link mode of the SFP/SFP+ port if the link fails. To function with some fiber-NICs or Media Converters, user has to
set the port Link mode to
“10GForce”
,
“1000 Force”
or
“100 Force”
.
Summary of Contents for NS4702-24P-4S-4X
Page 1: ...NS4702 24P 4S 4X User Manual P N 1072829 REV 00 01 ISS 14JUL14 ...
Page 23: ...23 Storage Temperature 10 70 degrees C Relative Humidity 5 95 non condensing ...
Page 164: ...164 Figure 4 8 2 Multicast Flooding ...
Page 183: ...183 Figure 4 8 14 IGMP Snooping VLAN Configuration Page Screenshot ...
Page 189: ...189 Figure 4 8 17 MLD Snooping Groups Information Page Screenshot ...
Page 208: ...208 Figure 4 9 6 QoS Egress Port Tag Remarking Page Screenshot ...
Page 218: ...218 Deletes the QCE The lowest plus sign adds a new entry at the bottom of the list of QCL ...
Page 229: ...229 Figure 4 9 18 Voice VLAN Configuration Page Screenshot ...
Page 299: ...299 Figure 4 11 17 Add User Properties Screen Figure 4 11 18 Add User Properties Screen ...
Page 336: ...336 Figure 4 14 2 LLDPMED Configuration Page Screenshot ...
Page 357: ...357 Figure 4 15 4 VeriPHY Cable Diagnostics Page Screenshot ...
Page 367: ...367 ...
Page 391: ...391 ...