135
Power Delivery
9.3.1
Non-Battery Backup Circuits
For applications not supporting battery back-up, this circuit not required. When so, follow these steps:
•
Pull DDR
CKE
pins high and leave
CKE
signals on 80331 as ‘no connects’. This keeps
SDRAM from entering a pseudo, self-refresh mode, which can cause a lock-up condition on
the SDRAM device.
•
Pull the
PWRDELAY
pin low through a 1.5 K pull-down. Pulling it low has the effect of keeping
the power fail state machine in reset, therefore not allowing the power fail sequence to ever occur.