INSYS GSM small 2.0
Functions
11.12.3.4
Exiting the Sleep Mode
Waking-up the INSYS GSM small 2.0 from sleep mode into normal mode (corre-
sponds with
AT+CFUN=1
) is performed as shown in Table 11 depending on the
sleep mode setting:
Sleep
mode
Event
AT+CFUN=0
AT+CFUN=5
or
AT+CFUN=6
AT+CFUN=7
or
AT+CFUN=8
Reset via reset terminal YES YES YES
RTS falling edge
YES
NO NO
Unsolicited result code YES YES
Temporary; device en-
ters sleep mode again
after 2 s (
AT+CFUN=7
)
or 10 minutes
(
AT+CFUN=8
)
Incoming connection
YES YES
Temporary; device en-
ters sleep mode again
following the termina-
tion of the connection
after 2 s (
AT+CFUN=7
)
or 10 minutes
(
AT+CFUN=8
)
Any AT command (ex-
cept
AT+CFUN=1
)
NO
Temporary; device en-
ters sleep mode again
after 2 s (
AT+CFUN=5
)
or 10 minutes
(
AT+CFUN=6
)
Temporary; device en-
ters sleep mode again
after 2 s (
AT+CFUN=7
)
or 10 minutes
(
AT+CFUN=8
)
Incoming SMS (for
AT+CNMI=1,1
); corre-
sponds with an unsolic-
ited result code
YES YES
Temporary; device en-
ters sleep mode again
after 2 s (
AT+CFUN=7
)
or 10 minutes
(
AT+CFUN=8
)
RTC alarm; corre-
sponds with an unsolic-
ited result code
YES YES
Temporary; device en-
ters sleep mode again
after 2 s (
AT+CFUN=7
)
or 10 minutes
(
AT+CFUN=8
)
AT+CFUN=1
NO YES YES
Table 11: Energy conservation modes – exiting the sleep mode
11.12.4
Power-Down Mode
The INSYS GSM small 2.0 is not registered in the GSM network in power-down
mode. The GSM engine disables itself and only the real-time clock (RTC) remains
active.
59