Minimate Pro Operator Manual
8
–5
3.
Communication with a
Minimate Pro
and your computer is configured using the
Communications
Setup
dialog box located under the
Unit
menu. Open the
Unit
menu and
choose
Communications
. The
Communications Setup
dialog box appears, as shown below:
If required, we will only adjust the
Port
dropdown menu. The other menus,
Baud Rate
,
Retries
,
and
Modem Type
should have the same settings as the dialog box pictured above. Ensure that the
baud rate on the unit is also set to
115200
by following these steps:
1.
Press the
Setup
key.
2.
Press the
Down Arrow
key until
View/Edit Preferences
is highlighted. Press the
Enter
key.
3.
Press the
Down Arrow
key until
Serial Baud Rate
is highlighted.
4.
If the value to the right of
Serial Baud Rate
is not
115200
, then press the
Right Arrow
key to edit this value to match the
Series IV Baud
rate shown in the image above.
5.
Press the
Enter
key to accept the changes.
6.
Press the
Cancel
key to exit the setup menu and return to the main display on the unit.
Step 7: Define the Contents of the Event Summary Report
Blastware
creates an
Event Summary Report
for each recorded Event.
Blastware
offers you a
wide degree of flexibility to define the contents and visual aspects of these reports. In this step, we
enter a new report title, choose a
Compliance Report Graph
, and measurement units.