Ver. 3.003
p47
CONCEPT IQ. PLUS Programmer’s Manual.
IMPORTANT NOTE: Do not select any options 1 to 5, unless a Dialer Reporting format has been selected.
1 - Alarms are reported via Dialer.
2 - Restores are reported via Dialer.
3 - Isolates are reported via Dialer. NOTE: Isolates are not reported when an Area is Armed in Home Mode.
4 - Opening reports only sent after alarm has occurred.
If this option is enabled, it takes priority over Options 5 and 6 with respect to reporting Openings.
5 - General Open/Close Reporting.
Areas to be included in General Open/Close reporting are defined in the General Open/Close Area List. Address 507.
6 - Area Openings/Closings (Offs/Ons) are reported via Dialer.
GENERAL OPEN/CLOSE AREA LIST
(FIRST TO OPEN / LAST TO CLOSE)
In Multi-Area systems, this list allows the programmer to select which Areas will be included for processing in General Open/Close
reporting. In Single Area systems, this list is ignored.
General Open Close reporting will be used if enabled in the Reporting Options; Address 506, Option 5.
Any number of Areas can be selected, but Area 1 must be included in the list.
When reporting in Contact ID format, General Open/Close reporting only uses the Area 1 Client Code programmed at Address 521.
1 - Include Area 1 in the General Open/Close Area List.
2 - Include Area 2 in the General Open/Close Area List.
3 - Include Area 3 in the General Open/Close Area List.
4 - Include Area 4 in the General Open/Close Area List.
MAXIMUM DIAL ATTEMPTS.
(1 - 16 ATTEMPTS)
This Address sets the maximum number of dialling attempts the system can make to contact the Central Monitoring Station or Domestic
Telephone.
The system will alternate between the Primary and Secondary Telephone numbers for each attempt.
This setting represents the total number of attempts on both Telephone numbers.
IMPORTANT NOTE: Regulatory authorities may limit this number. (In Australia, ACA specify a maximum of 10 attempts. ACA Approval will
be void if Max Attempts is set to a higher value)
When the maximum number of attempts has been reached, and no connection is made, the Comms Fail System Input will be activated.
The system will wait 30 minutes before attempting to dial again. (This wait period is a regulatory requirement)
507
508
1 - Yes
2 - Yes
3 - Yes
4 - No
5 - No
6 - No
(Option Data)
1 - Yes
2 - No
3 - No
4 - No
8 Attempts
(Value Data)
ADDRESS
DEFAULT
FUNCTION
(Data Type)