Ver. 3.003
p27
CONCEPT IQ. PLUS Programmer’s Manual.
No Reporting.
Go to Step 30
“User Programming”
t
t
Domestic Dialer.
Go to Step 21
“Dialer Options”
t
t
20.
PROGRAM THE AREA CLIENT CODE/S.
Area 1 / General Area ................................................................ NEXT 521
Area 2 ........................................................................................ NEXT 522
Area 3 ........................................................................................ NEXT 523
Area 4 ........................................................................................ NEXT 524
Program one or more 4 digit Client Codes. Default for Area 1 is 9999, all other Areas are
blank and will use the value from Area 1 or if required, a unique Client Code may be
programmed for each Area that is to Report. Client Code/s are provided by the Central
Contact ID.
Go to Step 20
Client Codes.
21.
PROGRAM THE DIALER OPTIONS.
NEXT 506
22.
PROGRAM THE GENERAL OPEN/CLOSE AREA LISTS.
NEXT 507
Required only if Dialer Option 5 -“General Open/Close Reporting” selected above.
DEFAULT:
Area 1.
Assign the required Area/s to the General Open/Close Area List: (NOTE: Area 1 must be included in the list)
1 - Include Area 1. (Enabled by Default)
3 - Include Area 3.
2 - Include Area 2.
4 - Include Area 4.
t
t
t
Option
Default
1
Alarms reported via Dialer.
Yes
2
Restores reported via Dialer.
Yes
3
Isolates reported via Dialer.
Yes
4
Report Open only after an alarm.
No
5
General Open/Close reporting.
No
6
All Area Opens/Closes reported via Dialer.
No
How to Enter Data.
Select Address: Key in the Installer PIN Code; Press
then enter the 3 digit Address
(A1 to A3 Lamps will flash to prompt for each digit). The current Data will be displayed.
Enter Data:
Enter the new Data
.. (1-16 digits) OR Option/s to Select/De-select
, then
. NOTE:
clears the current field of all data or settings ready for new data.