p30
Ver. 3.003 (24/4/03)
CONCEPT IQ. PLUS Programmer’s Manual.
29.
ENABLE/DISABLE THE KEYPAD EMERGENCY ALARMS REQUIRED TO ACTIVATE THE DIALER.
NEXT 899.
30.
PROGRAM THE USERS (Wireless Remote Key + Card)
Master:
NEXT 402
An Installer Code or Master User Code must be used to program the Users.
Other Users:
NEXT 403 to 495
Program a User.
1) Key in your PIN, then Select the User Number. Press
,
,
,
.(402 = Master. 403 to 495 = User 3 to User 95),
a User can have a Wireless Remote and/or a PIN
OR
a Card and/or a PIN. A seperate User Number is required if a User has a Wireless Remote and a Card
(different PIN numbers).
2a)
Wireless Remote Key
(if Required, used with Enhanced RF Terminals or RF Module)
Enrol the User Wireless Remote Key by pressing a button on the Remote Key within 30 seconds of selecting the User number.
Three short beeps will sound to confirm that the Remote Key has been enrolled and assigned to the selected User.
If the Remote Key is already assigned to another User, or is not recognised by the system, one long beep will sound to indicate a problem.
OR
2b)
User Card
(if required, used with Enhanced Access Terminals)
Present the card at the attached reader head and observe the tones.
High tones indicate acceptance, low tone indicate rejection of the card.
t
Step 30 Continued Next Page
t
Option
Default
2
Panic Alarms will activate the Dialer.
Yes
4
Fire Alarms will activate the Dialer.
Yes
6
Medical Alarms will activate the Dialer.
Yes
7
Duress Alarms will activate the Dialer.
No
No Reporting.
Go to Step 30
“User Programming”
t
t