CONCEPT IQ. PLUS Programmer’s Manual.
NEXT 23
Activate Walk Test.
Puts the system into Walk Test Mode. Any Zone activation causes Siren squawk and Zone Lamp to flash. Press <CLR> to exit.
The system will automatically exit from Walk Test if the “Walk Test Time” (Address 912) expires.
Walk Test only monitors for the Seal and Alarm (Un-seal) conditions. No indication of Zone Input Tamper state is provided.
NEXT 24
Auxiliary Control and Test.
Auxiliary number followed by
will toggle the Auxiliary Output On and Off.
0
= Siren Speaker output.
3
= Aux 2 (Gen purpose Aux on Controller)
1
= Aux 1 (Strobe output)
4 - 10 = Aux 4 to 10. (Gen purpose Auxiliaries on Expansion card)
NEXT 25
Trigger Test Report.
Triggers a Test Report to the Central Monitoring Station or the nominated “Domestic Dialer” Telephone.
NEXT 26
Activates the Battery Test.
Switches the Battery Charger Off for 5 seconds to test Battery voltage. 3 Beeps at end of Test = Battery OK. One long tone = Battery Voltage Low.
NEXT 27
Answer Call.
Causes the Controller to automatically answer the next incoming call and attempt to establish Upload/Download connection.
This operation will over-ride any other programming option that disables a remote Upload/Download connection.
6. MASTER USER OPERATIONS SUMMARY.
6.1
MASTER USER OPERATIONS
NEXT 33
View and/or Set the Time and Date.
Current Time & Date will be displayed in the sequence: hh:mm:DD:MM:YY:d. (Hours, Minutes, Day, Month, Year, Day-of-week)
1)
Enter the Time data (hh:mm) then
,
2)
Enter the Date data (DD:MM:YY) then
.
3)
Enter the Day of Week (1=Sunday - 7=Saturday) then
.
NEXT 4xx
User Programming. Refer to the following pages for details.
Refer to the User’s Manual for more information on these functions.