CONCEPT IQ. PLUS Programmer’s Manual.
Siren.
The Siren Speaker output supports a standard 8 Ohm Horn speaker
and can generate 4 different siren tones for Burglary, Fire, Medical &
Panic alarms. The Siren time is programmable and any System Input
Alarms that are programmed to activate the Siren may be differentiated
from Zone Input Alarms by a different Siren tone.
Auxiliaries.
Auxiliary outputs are extremely flexible with a range of versatile
programming options for Security and Building/Home automation. A
choice of over 50 “Auxiliary Types” provides for Auxiliaries to;
Annunciate different types of alarms, Indicate (mimic) individual Area or
Zone status, Indicate Entry, Exit, Auto-Arm & Zone Bypass conditions,
Follow TimeZones, etc.
For each individual Auxiliary the output logic and On/Off actions can be
tailored including an optional timer that can be programmed in Minutes
or Seconds.
Communications.
The system offers “Contact ID” or “Domestic” dialing options. For a
higher level of Dialer integrity a Secondary telephone number can be
programmed, Telephone line monitoring is provided and the maximum
number of dial attempts can be specified. A “Comms Fail” alarm is
activated if the line is tampered or the maximum attempts is reached.
Daily, Weekly or Monthly Test reports can also be sent at a specified
time of day, or triggered manually by a Master User.
The Installer can dial in to the system from a PC for Upload/Download
when required. Security is provided by a PIN code requirement, and
Callback and Fax Bypass options are available.
With the DTMF Card fitted, a User can dial in to the system, and using
their PIN code, can perform remote operations and obtain system
status information.
The IQ Plus provides two On-board Serial Ports, allowing connection of
a Programming Key or PC for Upload / Download or to a Printer to print
Review output.
Timers.
An extensive range of Timers are provided catering for; Individual Area
Exit/Entry delays, System Siren time, Keypad lockout time and AC fail
delay time. Four TimeZones are provided including provision for up to
10 Holiday dates and automatic Daylight Saving adjustment is also
catered for.
The TimeZones can be used to turn Auxiliaries On and/or Off and to
control Areas.
User Functions.
In addition to the User operations described in “Types of Users” below,
the system provides a number of options to simplify and/or enhance
the User operations and feedback.
These include; Auto-Isolate on Arming, Quick Arming, Key-switch Arm/
Disarm and Zone activity display on LED Terminals.