CONCEPT IQ. PLUS Programmer’s Manual.
1.1 SYSTEM OVERVIEW
The Concept IQ is an affordable, simple to use security system targeted at the domestic
and small commercial markets. The system has been designed for ease of use by the
Installer and the End User.
SYSTEM HARDWARE
The basic Control Module has the following hardware dimensions:
•
Zones:
8 standard Zone Inputs or 16 doubled Zone Inputs.
•
Auxiliaries:
Total of 3. 1 Siren speaker / 1 Strobe / 1 General purpose.
•
Serial Communications Port:
RS232.
•
External Device Bus.
•
System LAN:
Provides connectivity for up to 4 LAN Devices.
•
IO Expansion Bus.
•
Separate Tamper Input.
A variety of Peripheral devices can be connected directly to the Control Module:
•
Programming Key.
•
Plug-on Expansion Card options. 8 additional Auxiliaries and/or 8 additional Zones.
•
DTMF communications Card.
•
DTMF + Voice communications Card.
•
Serial Adapter Cable for connection to PC.
The System LAN supports the following LAN Modules:
•
Standard 16 Zone / 4 Area LED Terminal.
•
RF Terminal that adds 2 key or 4 key radio remote functionality.
•
Enhanced Terminal that adds access control.
FUNCTIONAL DESCRIPTION
Zone Inputs.
Zone Inputs are individually programmed to define how they are to be
processed. An appropriate “Zone Type” is chosen and additional
options relating to; Alarm Processing, Reporting, Siren, Pulse
counting, Testing, and type of Input Device can also be defined.
Global Zone options also allow system-wide parameters to be set for
Pulse Counting, End-Of-Line Resistor values and Zone Self Testing.
System Inputs.
System Inputs are available for monitoring Faults and System Alarms
such as; Power Problems, Cabinet & Siren Tampers, Communication
Problems, LAN & Battery Fuses, Zone Self-test Status and Keypad
Emergency Alarms (Panic, Fire, Medical & Duress).
System Inputs are also available for monitoring Door Forced and Door
Open Too Long (DOTL) alarms, allowing operation of auxiliaries and
other General Options.
Automatic Battery Testing is available and triggers the Low Battery
alarm if the test fails.
The Installer enables the Siren and Reporting (to Fault History and/or Reveiw or through the
dialer) options for each System Input as required.
Areas.
The system can be configured in Single Area or Multi Area Mode
according to the site requirements. Up to 4 Areas are available and
Zone Inputs can be assigned to one or more Areas. Each Area can be
armed in “AWAY” or “HOME” modes.
Each LED Terminal can be configured for Multi-Area mode or assigned
to a Single Area.
Review
General Review is a history of events available to the Upload/
Download software or direct to a Printer in real time (IQ Plus only see
Tables - Section 10). Events such as alarms, restores, tampers, open,
close and system inputs are time stamped and entered into Review.
General Review contains a maximum of 128 entries, once Review is
full, older events are lost as new ones are entered.
Unique to the IQ Plus is “Access Review” events such as REX button, Door Forced, Door
Open Too Long (DOTL), valid and invalid card read and access entry are all viewable (requires
an add-on to the Upload/Download software). Access Review contains a maximum of 42
entries, once Review is full, older events are lost as new ones are entered.
General Options can be set, to allow Access Review to be written to General Review, this
option should be used with caution because of the limited size of the Review buffer.
1. INTRODUCTION