Blom-Singer®
Indwelling TEP Occluder
37720-03F
| 9
stoma contamination or sepsis, which may require removal of the
device and/or appropriate antibiotics; accidental aspiration of the
device into the airway, which may require removal by a physician;
occasional extrusion of the device, requiring replacement after
dilation of the TE puncture and additional supervision of the
stoma care regimen; puncture dilation resulting in leakage of
fluids around the device; inflammatory reaction around the
puncture site and formation of granulation tissue; dislodgment of
the device and subsequent closure of the TE puncture; intractable
leakage around the device, requiring surgical revision or closure
of the puncture; difficulty swallowing; tearing or other damage to
the device from improper use; accidental ingestion of the device
into the esophagus and/or GI tract.
PRODUCT DESCRIPTION
The Blom-Singer Indwelling TEP Occluder is offered nonsterile.
Nonsterile product is not intended for primary placement
procedures.
The Blom-Singer Indwelling TEP Occluder is made of silicone,
a biocompatible material used in many medical products. This
device is latex-free.
The gel cap used for insertion of the device is made of a vegetable
base gelatin. Individual patient reactions to these materials may occur.
The Blom-Singer Indwelling Occluder, (diagram 1) consists of an
esophageal retention flange (diagram 1a), a tracheal retention
flange (diagram 1b), and a neck strap (diagram 1c).
Note: Since this is a non-speaking device, cleaning of the device
is not necessary. However, on the portion of the device that
shows out of the puncture, the patient may need to remove dried
mucus secretions using a tweezer.
In order to manage dryness and secretions of the airway, a heat
and moisture exchange system is recommended. If dry secretions
persist and require removal, it is recommended that the area of
crusting be humidified to prevent trauma to the tracheal tissue.
INSTRUCTIONS FOR USE
The following procedure is provided by Eric D. Blom, Ph.D. Please
refer to the diagrams located at the back of this instruction manual.
Summary of Contents for Blom-Singer Indwelling TEP Occluder
Page 1: ...37720 03F R3 Blom Singer Indwelling TEP Occluder MEDICAL PROFESSIONAL Instructions For Use...
Page 4: ...4 37720 03F...
Page 16: ...16 37720 03F...
Page 28: ...28 37720 03F...
Page 41: ...ObturatorTEPPermanentBlom Singer 37720 03F 41...
Page 53: ...Blom Singer TrajniTEPOkluder 37720 03F 53...
Page 65: ...Blom Singer TrajniTEPOkluder 37720 03F 65...
Page 77: ...NotranjeZapiraloBlom Singer TEP 37720 03F 77...
Page 78: ...78 37720 03F BLOM SINGER Blom Singer 1 2 Blom Singer InHealth Blom Singer Blom Singer...
Page 80: ...80 37720 03F Blom Singer InHealth Technologies Blom Singer Vaseline...
Page 81: ...O Blom Singer 37720 03F 81 Blom Singer 24...
Page 82: ...82 37720 03F 6 InHealth Technologies...
Page 83: ...O Blom Singer 37720 03F 83 Blom Singer Blom Singer Blom Singer Blom Singer 1 1 1b 1...
Page 86: ...86 37720 03F Blom Singer a 4a 4b 4c 4d 4e...
Page 87: ...O Blom Singer 37720 03F 87 1 3 2 3 5 Vaseline 4 1...
Page 88: ...88 37720 03F 5 1c...
Page 89: ...O Blom Singer 37720 03F 89 Eric D Blom 3 1b 6...
Page 90: ...90 37720 03F 6 InHealth Technologies...
Page 92: ...92 37720 03F...
Page 93: ...37720 03F 93 DIAGRAMS Diyagramlar Diagrame Dijagrami Diagrami 2 2a 1 a c b...
Page 94: ...94 37720 03F 4a 3 4b 4c 4e 4d...
Page 95: ...37720 03F 95 5 6...
Page 98: ...98 37720 03F...
Page 99: ...37720 03F 99...