TRITON CORE Product Manual |
Product Description
INGENIA | 2021-07-07 16:23:18
16
Parameter
Conditions / Comments
MIN
TYP
M
A
X
UNIT
I
DC(
TRI-
7)
Continuous phase
current in DC
mode (TRI-7/48-y-
P)
-6.3
—
6.
3
A
DC
I
TRA
(TRI
-7)
Continuous phase
current in
Trapezoidal mode
(TRI-7/48-y-P)
—
—
5.
6
A
RMS
I
SIN(
TRI-
7)
Continuous phase
current in
Sinusoidal mode
(TRI-7/48-y-P)
—
—
5.
6
A
RMS
I
PK(
TRI-
1)
Peak phase
current (TRI-1/48-
y-P)
Peak time = continuous.
No heatsink required. Limited
by ADC range.
-1
—
1
A
DC
I
PK(
TRI-
4)
Peak phase
current (TRI-4/48-
y-P)
Peak time = continuous.
Limited by ADC range.
-5
—
5
A
DC
I
PK(
TRI-
7)
Peak phase
current (TRI-7/48-
y-P)
Peak time = 5 s
-8.5
—
8.
5
A
DC
η
NO
M
Efficiency
Phase current = 7 A
RMS
—
—
9
7
%
4.5.4 System monitoring
Parameter
Conditions / Comments
MIN
TYP
MAX
UNIT
I
RANGE(
TRI-1)
Phase current sensing
range (TRI-1/48-y-P)
-1.02
—
1.02
A