TRITON CORE Product Manual |
Signalling LEDs
INGENIA | 2021-07-07 16:23:18
34
ERROR LED
state*
Concept
Description
Off
No error
Device is in working condition.
Single flash
Warning limit reached
At least one of the error counters of the CAN
controller has reached or exceeded the warning
level (too many error frames).
Double flash
Error control event
A guard event (NMT-slave or NMT-master) or a
heartbeat event (heartbeat consumer) has
occurred.
Triple flash
Sync error
The sync message has not been received within
the configured communication cycle period time
out.
On
Bus off
The CAN controller is bus off.
RUN LED indicates the status of the CANopen network state machine. Next table shows the meaning of the RUN
LED states:
RUN LED
state*
Concept
Description
Off
Off
The device is switched off
Blinking
Pre-operational
The device is in state PREOPERATIONAL
Single flash
Stopped
The device is in state STOPPED
On
Operational
The device is in state OPERATIONAL
*See a detailed description of the states in the next table:
* Possible LED states
Description
ON
The LED is always on
OFF
The LED is always off